Lab reports
A lab report is a test bigger than one product: sixty plates on one scale, fourteen bars in one press frame. Each one prints its method, its sample, the limit it was held to, what we could not control, and the raw data as a CSV you can check against us.
How the lab works
- 01Every unit is bought at retail or flagged as a maker sample. Receipt, serial or lot go in the log before it is unboxed.
- 02It is measured on arrival on the instruments listed below, each with a serial and a calibration date.
- 03The pass limit is written down before the test starts, and it does not move afterwards.
- 04The CSV is published exactly as recorded. Corrections are logged, never quietly edited.
Raw data and calibration owned by Luis Ortega, lab manager.
The lab in numbers
- Published with raw CSV
- 1 reports
- Serials and dates below
- 10 instruments
- Concrete test floor
- 1,900 sq ft
- Removed from any CSV
- 0 rows
All reports
Newest first-
Lab report 012
Plates · 1 pass, 1 fail in the results tablePlate weight tolerance: 60 plates on a calibrated scale
Headline finding We weighed 60 plates from six brands at 0.1 g resolution. Twelve were outside the IPF tolerance for their class.
- Tested
- Published
- Updated
Instruments on the floor
How they are used →Last calibration logged 2026-11-15 (digital calipers, 200 mm). Next due 2027-03-10 (high-speed camera, 240 fps). An instrument past its due date is taken off the floor until it comes back.
| Instrument | Serial | Resolution | Used for | Calibrated | Due |
|---|---|---|---|---|---|
| Bench scale | BS-60K-41172 | 0.1 g | Plates, bars, dumbbells, kettlebells | ||
| Digital calipers, 200 mm | DC-200-88310 | 0.01 mm | Shafts, sleeves, handles, hole diameters | ||
| Mitutoyo depth gauge | MT-DG-20945 | 0.01 mm | Knurl depth, permanent set against a straightedge | ||
| Shore A durometer | SA-1207-554 | 0.5 HA | Bumpers, pads, shoe soles | ||
| Coating thickness gauge | CT-FN-30781 | 1 µm | Cerakote, chrome, zinc, powder coat | ||
| Load cell, 20 t press frame | LC-20T-6618 | 10 N | Static loads, permanent set, rack deflection | ||
| High-speed camera, 240 fps | HS-240-07734 | 4.2 ms per frame | Drop tests, bar path, plate bounce | ||
| Sound level meter, class 2 | SL-C2-51490 | 0.1 dB | Drop noise, rower and bike noise at 1 m | ||
| Torque wrench | TW-340-21865 | 1 N·m | Rack and bench hardware at build | ||
| Thermal probe | TP-K-90217 | 0.1 °C | Recovery devices, motor housings |
Certificates on file at 2418 East Cesar Chavez St, Austin, TX 78702. Ask for a copy at desk@thegymnautilus.com.